12 Threads found on edaboard.com: Unbalance Phase
There are two distinct unbalance conditions: The three phases have unequal peak voltages AND/OR the phase relations between the phases are not equal. In general, we expect the load too be symmetric on the three phases. This condition is often not fulfilled. The effect depends on the source impedance. Your (...)
It's a 1:1 Balun Transformer that is used to convert Balanced-to-unbalanced ( or vice versa) has no effect on impedances. But amplitude and phase unbalance specs. are very poor due to its' wideband characteristics.Irecommend you to use a narrowband one which is more convenient at the frequency where you would at. Because if you us
Hi, all, I found that the phase and gain unbalance will go back to 90 degree and 0dB after complex filter from simulation, but what's the reason, could anyone show me the point? Thanks in advance
i faced some problems when i try to implement the pll block in simulink model. so, i need help. My confusions are: 1. How can i estimate positive sequence voltage from 3 phase unbalance voltage source? 2.how can i simulate pll circuit? THANK YOU.
I don't found any link in your post I was referring to "Similar Threads" on the bottom of the page. E.g. the first thread "how to detect phase unbalance" is discussing different options for 3-phase supply monitoring. And there are surely more, because this is a serial topic at edaboard. In my view, it's necessary to clarify the s
Here is list and functions of normally used 3-phase Protection relays Control and Automation For industrial applications ED.03 Electronic relays GE POWER CONTROLS Ltd Earth leakage relays..............F13 Integral protection relay for three-phase lines.............F14 unbalance and phase failure (...)
hi, Can any body suggest how detect phase unbalance, Means In three phase system if one of the phase has the 10% less volt than two others. Anand
I/Q Amplitude mismatch appear if: - unbalance in the RF splitter used to divide the incoming RF signal equally between the I and Q paths which may introduce gain differences. - The quadrature 90 phase-splitter used to generate the I and Q Local-Oscillator (LO) signals that drive the I and Q channel mixers may not be exactly 90. Furthermore, the
dear techs, do u have any idea about fault diagnosis in 3 phase electric lines using microcontroller... Dear sivasujith In three phase electric lines lot fault you have to concider ex)Voltage unbalance,phase sequence change,missing Neutral,No load...you want to diagnosis these faults, yo
There are some method to measure the I/Q unbalance. 1) You can use a Netwrok analyzer. In this case you have to enter not in the two ports, but after the generator (usually is possible in the main network). So you can measure the unbalance (phase and amplitude). 2)If the frequency is under 2.7 GHz you can use the AD8302 RF/IF gain and (...)
A three phase current transformer is useful for situations where you might have an unbalance load, i.e., the phase currents are not equal. In a motor, you can expect the phase currents to be nearly identical so a single current transformer should suffice in most applications.
At –20dB conversion gain you have a problem there. Could be a phase unbalance. This document may help you how to improve conversion gain at low powers.